Firedor Smoke is fire-rated up to E120 and has been tested to BS EN 1634-1:2014 + A1:2018. Additionally, it has undergone further testing to BS EN 1634-3:2004 + AC:2006, earning up to E120Sa classification, which signifies compliance with the ambient smoke performance standard.

Comprising of 1.2mm ‘Rustec’ steel sheets, the leaf skins are mechanically interlocked and internally bonded, proving greater stability and protection against de-lamination.

  • Fire-rated up to E120
  • Available as PAS 24:2016
  • Over 150 colours as standard
  • Smoke-rated up to E120Sa
Unique Range Features

World class steel doors
Trustpilot rated Excellent
1 year warranty
Easy fit doors
10-15 day lead time*

Download Tech Specs
C e logo
Dhfjpg

Product Features

Height

Single - up to 2.76m
Double - up to 2.76m

Width

Single - up to 1.2m
Double - up to 2.3m

Leaf Thickness

44mm deep leaf skin

I6
Fire resistance

Fire-rated up to E120

Strongdor Icons Acoustic
ACOUSTIC RATING

Up to 36dB rating

NBS Specification

Further information

Features
Videos
Downloads

Frame
Manufactured from lightweight, high tensile 1.5 mm thick ‘Rustec’ steel.
Adjust 2-Fit side expander system that offers up to 12mm expansion to the structural opening.

Leaf
44mm door leaf thickness incorporating an integrated astragal for added security. Comprising of 1.2mm ‘Rustec’ steel sheets, the leaf skins are mechanically interlocked and internally bonded, proving greater stability and protection against de-lamination.

Threshold
Firedor Smoke is supplied with our 96mm threshold as standard.
Smoke doors cannot be supplied without a threshold.

Finish
Supplied inclusive of a powder coated finish in a standard colour. Full range of RAL and BS colours available.

Door Ironmongery
Grade 13 stainless steel, twin bearing template drilled butt hinges with integral high security dog bolts are fitted as standard with CE marking. 316 Stainless steel hinges upgrade available.
Other hardware available includes:
Briton 5720 sashlock
Stainless steel lever handles
Fire-rated closers
Flush bolts on the inactive leaf on doubles

Strongdor Steel Door Single Install Thumbnail

Single Door Installation

This video contains detailed, step-by-step instructions for the safe installation of a Strongdor Steeldor single door-set. Please pay particular attention to the safety instructions.

Strongdor Double Door Install Thumbnail

Double Door Installation

This video contains detailed, step-by-step instructions for the safe installation of a Strongdor Steeldor double door-set. Please pay particular attention to the safety instructions.

Touching Up Paintwork

Touching up Paintwork

A demonstration of how to sue the touch up kit supplied with your steel door-set.

Strongdorcolouroptions23

Standard Colours & Coatings

View File

Similar Products

Thermal and Fire Rated Steel Door

Find out More

Fire Rated Internal Steel Door

Find out More

PAS 24 - Secured By Design Steel Door

Find out More

Any questions about this product?

Speak to an expert now

Telephone icon 01524 727000

Hardware Options

View our popular items of door furniture and security hardware.

Untitled 1
Dorma Ts83 Square

Over 150 colours available

View Colour Options

You might be interested in

Blue Door Icon

Thermal and Fire Rated Steel Door

View Door
Firedor Internal Listing

Fire Rated Internal Steel Door

View Door

Related Articles

East Grinstead Fc15

Fire Rated Steel Doors Vs Panic Exit Steel Doors

In summary Fire rated doors are used as a barrier to withhold smoke and fire for a specified period of time. Whereas a Fire exit is a steel door fitted with panic exit (push bars) used as a means of escape rather than to keep a fire in.

View Article
Clear Opening Mobile

What is the Clear Opening Width and how do I work it out?

The clear opening width is the size of the gap any persons/objects can pass through freely when the door is opened to its full potential (most doors will usually only open to a 90-degree angle).

View Article
Strongdor Fire Door Safety Week Red Door

Close the door on fire – Fire Door Safety Week 2022

Fire Door Safety Week was first launched in 2013, aiming to raise awareness of the critical role that fire doors play in saving lives and protecting property in the unfortunate event of a fire. If the worst happens and fire breaks out then seconds can make a huge difference.

View Article

Frequently Asked Questions

Who is responsible for ensuring the sales quotation meets the specification and building regulations, including location and method of installation?

It is the customer’s responsibility to ensure all details within the sales quotation / sales order meet the exact specification and / or original enquiry and are compliant with current building regulations including location and method of installation.

We are here to help and advise only and cannot accept responsibility for discrepancies after the order is confirmed.

Strongdor Terms and Conditions

Do Strongdor offer a site measuring or an installation service?

No, Strongdor are a supply only manufacturer and therefore unfortunately don't offer site surveys or installation. However we can recommend local installers in your area from our Doorfit Network, who will be happy to help.

Complete our quotation request form, mention you are looking for installation and we will put you in touch!

Request a Quote

Trade customer?

Purchase steel doors regularly? Speak to one of our account managers and request to set up an account today.

Apply today

Stay in the know

Join our mailing list for industry news, product updates and more

This site uses cookies to monitor site performance and provide a more responsive and personalised experience. You must agree to our use of certain cookies. For more information on how we use and manage cookies, please read our Privacy Policy.